H3.X Lightweight IMA Computer
For data concentrator and battery or fuel cell management applications
At a glance
- Architecture
- Single channel
- Mass
- 250 g
- Power
- 8 W maximum
- Isolation
- Non-isolated
- RTOS
- ARINC 653 Part 1

Drag to rotate, scroll to zoom
The H3.X Computer completes the family as a highly optimized, ultra-lightweight single-channel computer for auxiliary and distributed systems.
Key capabilities
- Distributed architectures: engineered for data concentrators and battery, fuel cell, and powertrain control and prognostic health management.
- End system safety: capable of supporting safety-critical functions from upstream to downstream processing.
- Optimized for auxiliary applications: the H3.X omits galvanic isolation, allowing a significant reduction in Bill of Materials (BoM) cost where the installation does not require it.
- Ultra-low Size, Weight, and Power (SWaP): where quantity and SWaP sensitivity are high, but compromising reliability and safety is not an option.
System integration
In a distributed avionics architecture, the H3.X is a smart data concentrator. It collects high-frequency sensor readings, such as battery cell or fuel cell data, and transmits them over the aircraft network.
Modular platform
The H-series IMA computers are modular by design and share the same Hover Real-Time Operating System (H-RTOS) and Hover Software Development Kit (H-SDK). The H3.X is compatible with every H-series main processing board, including the safety-critical and edge inference boards.
Specifications
Physical
4 items
| Dimensions | 110 × 60 × 30 mm |
|---|---|
| Mass | 250 g |
| Cooling | Conduction-cooled, no forced air |
| Mounting | Three-point flange, dedicated grounding point |
Electrical
5 items
| Input voltage | 18.0 V to 32.2 V DC steady state |
|---|---|
| Nominal voltage | 28 V DC |
| Power consumption | 6.4 W typical, 8 W maximum |
| Galvanic isolation | Non-isolated, optimized for size, weight, and cost |
| Connectors | Modular, high-reliability EN4165 |
Processing
4 items
H3.0
| Main processing board | Safety-critical |
|---|---|
| Processors | 2 × Arm Cortex-A72 @ 800 MHz |
| Memory and storage | 16 GB SDRAM and 1 GB NOR flash |
| Design assurance | DAL A |
H3.1
| Main processing board | Edge inference |
|---|---|
| Processors | 2 × Arm Cortex-A76 @ 1.8 GHz and 2 × Arm Cortex-A55 @ 1.5 GHz |
| Memory and storage | On-board eMMC |
| Design assurance | DAL C |
Environmental qualification (RTCA DO-160G)
15 items
| 4.5 Temperature / 4.6 Altitude | Category D2 |
|---|---|
| 5. Temperature variation | Category B |
| 6. Humidity | Category B |
| 7.2 Operational shock / 7.3 Crash safety | Category E |
| 8. Vibration | Category U |
| 10. Waterproofness | Category W |
| 12. Sand and dust | Category S |
| 16. Power input | Categories B and Z (2.5 ms power interruption) |
| 17. Voltage spike | Category A |
| 19. Induced signal susceptibility | Category ZN |
| 20. RF susceptibility | Radiated Y, conducted R |
| 21. RF emissions | Categories H and Q |
| 22. Lightning-induced transient susceptibility | B3K3L3 |
| 25. Electrostatic discharge | Category A |
| 26. Fire, flammability | Category C |
Specifications are typical values and subject to change. Contact us for the controlled datasheet before committing to a design.
Interfaces
Ethernet
2 × 1 GbE, IEEE 802.1 TSN
CAN FD / isoSPI
Configurable on the fly: 4 CAN FD, or 2 CAN FD plus 4 isoSPI
EIA-485
1, half-duplex, 50 Mbps
Analog inputs
8
General-purpose I/O
1 input / 5 outputs
Power
1 × 28 V input and ground
Interface availability and channel counts vary by configuration. Full pin-level detail is provided in the Interface Control Document.
Design assurance and qualification
- RTCA DO-160G environmental qualification
- RTCA DO-178C Level A (software)
- RTCA DO-254 Level A (complex hardware)
- RTCA DO-297 Integrated Modular Avionics (IMA) guidance
- TSO-C153a IMA platform authorization
Typical applications
- Battery management
- Data concentrator
- Fuel cell management
- Powertrain controller
Inside the H3.X